SPECTROPHOTOMETER

 Spectrophotometer Model LUV-100A
  • Optical System- Double Beam
  • Wavelength Range- 190 ~1100 nm
  • Spectral Bandwidth- 2 nm (5nm, 4nm, 1nm, 0.5nm optional)
  • Detector- Silicon photo diode
  • Photometric Accuracy- ±0.3%T (0~100%T); ±0.002A (0~1A)


LUV-100A.jpg
 LUV-1000E
  • Optical System- Double Beam
  • Wavelength Range- 190 - 900nm
  • Spectral Bandwidth- 0.5, 1, 2, 5nm (Variable slit)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
LUV_1000E.jpg
 LUV-1000C
  • Optical System- Double Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 2nm (fixed slit)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
LUV_1000C.jpg
 LUV-1000D
  • Optical System- Double Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 0.5, 1, 2, 5nm (Variable slit)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)

LUV_1000D.jpg
 LUV-1000A
  • Optical System- Split Beam
  • Wavelength Range- 190-1100nm
  • Spectral Bandwidth- 2nm fixed slit
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)
LUV_1000A.jpg
 LUV-1000B
  • Optical System- Split Beam
  • Wavelength Range- 190-1100nm
  • Spectral Bandwidth- 0.5, 1, 2, 5nm (variable slit)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)
LUV_1000B.jpg
 LUV-100A
  • Optical System- Double Beam
  • Wavelength Range- 190 ~1100 nm
  • Spectral Bandwidth- 2 nm (5nm, 4nm, 1nm, 0.5nm optional)
  • Detector- Silicon photo diode
  • Photometric Accuracy- ±0.3%T (0~100%T); ±0.002A (0~1A)
     
LUV-100A.jpg
 LUV-200A
  • Optical System- Single Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 2nm (5nm, 4nm, 1nm, 0.5nm optional)
  • Detector- Silicon photodiode
  • Photometric Accuracy- 0.3%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
LUV200aA.jpg
 LUV-100B
  • Optical System- Double Beam
  • Wavelength Range- 190~900nm
  • Spectral Bandwidth- 0.1nm, 0.2nm, 0.5nm, 1.0nm, 2.0nm
  • Detector- Photomultiplier
  • Photometric Accuracy- ± 0.3%T (0~100%T), ± 0.002A
         (0~0.5A), ± 0.004A    (0.5A~1A)
luv100B.jpg
 LUV-200B
  • Optical System- Single Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 2nm (5nm, 1nm optional)
  • Detector- Silicon photo-diode
  • Photometric Accuracy- 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
UVS200b.jpg
 LUV-300
  • Optical System- Single Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 2nm (5nm, 1nm optional)
  • Detector- Silicon photo-diode
  • Photometric Accuracy- 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
luv300.jpg
 L-VIS-400
  • Optical System- Single Beam
  • Wavelength Range- 320 - 1100nm
  • Spectral Bandwidth- 2.0nm (5nm, 1nm optional)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.5%T (0 - 100%T), ± 0.002A (0 - 0.5A), ± 0.004A (0.5A - 1A)
vis400.jpg
 
 