| Spectrophotometer Model LUV-100A |
- Optical System- Double Beam
- Wavelength Range- 190 ~1100 nm
- Spectral Bandwidth- 2 nm (5nm, 4nm, 1nm, 0.5nm optional)
- Detector- Silicon photo diode
- Photometric Accuracy- ±0.3%T (0~100%T); ±0.002A (0~1A)
|
 |
| LUV-1000E |
- Optical System- Double Beam
- Wavelength Range- 190 - 900nm
- Spectral Bandwidth- 0.5, 1, 2, 5nm (Variable slit)
- Detector- Silicon photodiode
- Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
|
 |
| LUV-1000C |
- Optical System- Double Beam
- Wavelength Range- 190 - 1100nm
- Spectral Bandwidth- 2nm (fixed slit)
- Detector- Silicon photodiode
- Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
|
 |
| LUV-1000D |
- Optical System- Double Beam
- Wavelength Range- 190 - 1100nm
- Spectral Bandwidth- 0.5, 1, 2, 5nm (Variable slit)
- Detector- Silicon photodiode
- Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
|
 |
| LUV-1000A |
- Optical System- Split Beam
- Wavelength Range- 190-1100nm
- Spectral Bandwidth- 2nm fixed slit
- Detector- Silicon photodiode
- Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)
|
 |
| LUV-1000B |
- Optical System- Split Beam
- Wavelength Range- 190-1100nm
- Spectral Bandwidth- 0.5, 1, 2, 5nm (variable slit)
- Detector- Silicon photodiode
- Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)
|
 |
| LUV-100A |
- Optical System- Double Beam
- Wavelength Range- 190 ~1100 nm
- Spectral Bandwidth- 2 nm (5nm, 4nm, 1nm, 0.5nm optional)
- Detector- Silicon photo diode
- Photometric Accuracy- ±0.3%T (0~100%T); ±0.002A (0~1A)
|
 |
| LUV-200A |
- Optical System- Single Beam
- Wavelength Range- 190 - 1100nm
- Spectral Bandwidth- 2nm (5nm, 4nm, 1nm, 0.5nm optional)
- Detector- Silicon photodiode
- Photometric Accuracy- 0.3%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
|
 |
| LUV-100B |
- Optical System- Double Beam
- Wavelength Range- 190~900nm
- Spectral Bandwidth- 0.1nm, 0.2nm, 0.5nm, 1.0nm, 2.0nm
- Detector- Photomultiplier
- Photometric Accuracy- ± 0.3%T (0~100%T), ± 0.002A
(0~0.5A), ± 0.004A (0.5A~1A)
|
 |
| LUV-200B |
- Optical System- Single Beam
- Wavelength Range- 190 - 1100nm
- Spectral Bandwidth- 2nm (5nm, 1nm optional)
- Detector- Silicon photo-diode
- Photometric Accuracy- 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
|
 |
| LUV-300 |
- Optical System- Single Beam
- Wavelength Range- 190 - 1100nm
- Spectral Bandwidth- 2nm (5nm, 1nm optional)
- Detector- Silicon photo-diode
- Photometric Accuracy- 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
|
 |
| L-VIS-400 |
- Optical System- Single Beam
- Wavelength Range- 320 - 1100nm
- Spectral Bandwidth- 2.0nm (5nm, 1nm optional)
- Detector- Silicon photodiode
- Photometric Accuracy- ± 0.5%T (0 - 100%T), ± 0.002A (0 - 0.5A), ± 0.004A (0.5A - 1A)
|
 |
|
|
| |
|
|